Sign In | Join Free | My enlightcorp.com |
|
Place of Origin : Dalian China
Brand Name : oem
Certification : ISO CE
Model Number : 9888
MOQ : 1 set
Price : Negotiable
Packaging Details : Carton
Delivery Time : 3-5 days
Payment Terms : T/T Western Union MoneyGram
Supply Ability : 200 sets/month
cel phone : 17785279887
celphone : 18878952222
mobile : 18878952222
cel. : 18878952222
tel : 18878952222
--------------------------------------------------------
www.meterytech.com
Photo of vortex steam flow meter MT100VX
Parameter of vortex flow meter | |||||
Measured Mediums | liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.) | ||||
When the dryness of saturated steams ≥85%, they can be seen as unidirectional. | |||||
Temperature of Mediums | - 40°C ~ + 350°C | ||||
Pressure of Mediums | 1.6MPa, 2.5MPa, 4.0 MPa | ||||
For over 4.0 MPa, please contact us freely, for it needs special customization. | |||||
Accuracy | 1.0; 1.5 | ||||
Span Rate | 1:8 ~ 1:30(compared with the standard atmospheric pressure) | ||||
1:8 ~ 1:40 ( compared with the nominal temperature water) | |||||
Flow Range | Liquids: 0.4 ~ 7.0 m/s | ||||
Gases: 4.0 ~ 60.0 m/s | |||||
Steams: 5.0 ~ 70.0 m/s | |||||
Nominal Diameter | DN 25, 40, 50, 65, 80, 100, 125, 150, 200, 250,300 mm | ||||
Materials | 1Cr18Ni9Ti | ||||
Reynolds No. | Normally, 2*104 ~ 7*106 | ||||
Resistance Coefficient | Cd ≤ 2.6 | ||||
Licensed Vibration Acceleration | LUGB type ≤ 0.2g | ||||
Class of Protection | IP65 | ||||
Class of Explosion-Proof | Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 | ||||
Explosion Suppression: Exid II CT4 | |||||
Conditions of Surroundings | Temperature of Surroundings: | Non-Explosion Proof Surroundings: -40°C~ +55°C | |||
Explosion-Proof Surroundings: -20°C~ +55°C | |||||
Relative Humidity: | ≤ 85% | ||||
Atmospheric Pressure: | 86 ~ 106 kPa | ||||
Power Supply | Non-Explosion Proof Type | Pulse type: | +12 VDC ( the output current is 4 ~ 20mA) | ||
Current type: | +24 VDC ( the output current is 4~ 20mA) | ||||
Explosion-Proof Type | Current type: | +24 VDC ( the output current is 4~20mA) | |||
Output Signal | Frequency pulse signal 2~3000Hz, low level voltage ≤1V, high level voltage ≥ 6V | ||||
Two-wire system 4 ~ 20mA signal (isolation output), load ≤ 500Ω. |
Measuring range of vortex flow meter MT100VX
Measure range of vortex flow meter | ||
Diameter (mm) | Water | Gases in the Normal Temperature and Pressure |
Range of Standard Measurement (m3/h) | Range of Standard Measurement (m3/h) | |
25 | 2 ~ 16 | 8~60 |
32 | 1.5~15 | 14~100 |
40 | 3~30 | 18~180 |
50 | 4~40 | 30~300 |
65 | 6~60 | 50~500 |
80 | 13~130 | 70~700 |
100 | 20~200 | 100~1000 |
125 | 36~360 | 150~1500 |
150 | 50~500 | 200~2000 |
200 | 100~1000 | 400~4000 |
250 | 150~1500 | 600~6000 |
300 | 200~2000 | 1000~10000 |
Installation cautions
Pipes must be fully filled with liquids, it is essential that pipes remain fully filled at all times, other ise flow rate
indications may be affected and measurement errorsmay be caused.
Product View
Installation Length
Wafer Connection
At your service
Our principle is "Reputation from Services&Quality is the lifeline of enterprise", so besides our product, satisfactory
services is our another competitive hand.
--------------------------------------------------------
www.meterytech.com
To World, METERY is Just A Company, But to METERY, You Are The World...
![]() |
Vortex steam flow meter MT100VX series from METERY TECH. Images |